Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number

Goodman CK36-1A air conditioner heat pump outside unit Parts

Here are the diagrams and repair parts for Goodman CK36-1A air conditioner heat pump outside unit, as well as links to manuals and error code tables, if available.

Goodman CK36-1A air conditioner heat pump outside unit
By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for CK36-1A Air Conditioner Heat Pump Outside Unit

Goodman Air Conditioner Heat Pump Outside Unit CK36-1A FAQs

Goodman model CK36-1A is a 3-ton outdoor air conditioner/heat pump unit. In Goodman model numbers, the “36” typically indicates about 36,000 BTU/hr of cooling capacity, and 36,000 BTU/hr equals 3 tons.

How we determine tonnage from the model number

Most central AC and heat pump outdoor units use a capacity code in the model number:

  • 18 = about 18,000 BTU/hr (1.5 tons)
  • 24 = about 24,000 BTU/hr (2 tons)
  • 30 = about 30,000 BTU/hr (2.5 tons)
  • 36 = about 36,000 BTU/hr (3 tons)
  • 42 = about 42,000 BTU/hr (3.5 tons)
  • 48 = about 48,000 BTU/hr (4 tons)
  • 60 = about 60,000 BTU/hr (5 tons)
Quick conversion table
Cooling capacity Tonnage
24,000 BTU/hr 2 tons
36,000 BTU/hr 3 tons
48,000 BTU/hr 4 tons
Why it matters

Matching the correct tonnage helps ensure proper comfort and efficiency. A mismatched outdoor unit can lead to poor humidity control, short cycling, higher energy use, and coil icing.

Confirm the exact rating for your specific unit

We recommend checking the unit’s data plate and the owner's manual for the exact cooling capacity and any approved indoor coil or air handler matches for CK36-1A.

Last updated: February 2026

AC spare parts for a Goodman CK36-1A outdoor air conditioner/heat pump unit range from a few dollars for small hardware to hundreds or thousands for major components. For this model, small items like a grommet B1339530 are typically low-cost, while motors, controls, coils, and compressors cost much more.

Typical AC part cost ranges (parts only)

These are common price ranges for residential outdoor units; exact pricing depends on brand, capacity, and availability.

  • Small items (grommets, screws, wire terminals, fuses): $5 to $30
  • Capacitors and contactors: $15 to $150
  • Sensors, switches, and relays: $20 to $200
  • Fan motor: $100 to $400
  • Control board (if used on your setup): $150 to $700
  • Compressor or coil: $800 to $3,000+
What changes the price the most
  • Part type and size: A compressor or coil costs far more than electrical hardware.
  • Match to your exact model: CK36-1A-SPECIFIC parts fit correctly and prevent wiring or mounting issues.
  • Labor and refrigerant work: Outdoor unit repairs that involve sealed-system work add significant service cost.
Quick examples for this CK36-1A parts list
Example part on this model page What it does Typical cost impact
Grommet B1339530 Protects wires/tubing from rubbing on metal Low
Appliance spray paint (bahama beige) B260S8291 Cosmetic touch-up for cabinet panels Low to moderate
Why it matters

Knowing the typical range helps you decide whether to replace a single component (like a capacitor or fan motor) or plan for a larger repair. For higher-cost repairs, confirming the correct part by model number and using the wiring diagram in the owner's manual prevents repeat failures and miswiring.

Last updated: February 2026

A Goodman AC unit typically lasts 12 to 15 years. With consistent maintenance (clean coils, correct refrigerant charge, good airflow) and proper installation, many systems run 15 to 20 years before major repairs or replacement become more cost-effective. For model CK36-1A, follow the maintenance intervals in the owner's manual.

What affects lifespan the most
  • Installation quality (correct sizing, airflow, refrigerant charge)
  • Outdoor coil condition (dirt, grass clippings, cottonwood, salt air)
  • Electrical health (tight connections, good capacitor/contactor)
  • Run time and climate (long cooling seasons shorten life)
  • Maintenance frequency (annual service plus seasonal cleaning)
Simple maintenance that adds years

We recommend these habits for a Goodman outdoor unit like the CK36-1A:

  • Rinse the outdoor coil gently (power off first) and keep the fins clear
  • Keep 18 to 24 inches of clearance around the condenser
  • Replace or clean the indoor air filter on schedule (restricted airflow strains the system)
  • Keep the unit level and the base free of leaves and debris
  • Have a technician check refrigerant charge and electrical components annually
When replacement starts to make sense
If you notice What it often means Typical next step
Frequent breaker trips or burnt wiring smell Electrical issue or compressor stress Professional diagnosis and repair
Rising electric bills with normal usage Efficiency loss, dirty coils, airflow problems Cleaning, tune-up, airflow check
Repeated refrigerant leaks Coil or line set deterioration Leak repair vs. replacement decision
Loud grinding or hard starts Fan motor/compressor wear Repair estimate and cost comparison
Why it matters

Once an AC reaches the 12 to 15 year range, small issues (dirty coils, weak electrical parts, airflow restrictions) can turn into expensive failures. Staying ahead of maintenance protects the compressor and helps your Goodman system cool reliably.

Last updated: February 2026

A 3-ton central AC (about 36,000 BTU/hr) typically cools about 1,500 to 2,000 sq ft in average conditions. For a Goodman CK36-1A outdoor unit, the real coverage depends on your home’s insulation, sun exposure, ductwork, ceiling height, and local climate; use the sizing guidance in the owner's manual as your baseline.

Quick sizing range (what most homes see)
  • 1,500 to 1,800 sq ft: common target range for many homes
  • 1,800 to 2,000 sq ft: possible with excellent insulation, tight windows, and good duct design
  • Below 1,500 sq ft: common in very hot climates, high ceilings, lots of glass, or leaky/under-insulated homes
  • Above 2,000 sq ft: usually needs a load calculation and often a larger system or zoning
What changes the square footage the most
  • Insulation and air sealing (attic, walls, rim joists, weatherstripping)
  • Ceiling height (taller ceilings increase the air volume you must cool)
  • Windows and sun exposure (large west-facing glass adds major heat gain)
  • Duct condition (leaks, poor returns, undersized ducts reduce delivered cooling)
  • Humidity and climate zone (humid regions need more latent capacity)
  • Internal loads (occupants, cooking, electronics)
Rule-of-thumb table (use for a fast estimate)
Home condition Typical sq ft per ton 3-ton estimate
Hot climate or older/leaky home 400 to 500 1,200 to 1,500
Average insulation and windows 500 to 600 1,500 to 1,800
Very efficient/tight home 600 to 700 1,800 to 2,100
Why it matters

Oversizing can cause short cycling, poor humidity control, and uneven temperatures. Undersizing can run constantly and still miss the set temperature. The best match comes from a room-by-room load calculation (often called Manual J) and confirming your CK36-1A’s matched indoor coil and airflow settings in the owner's manual.

Last updated: February 2026

For a Goodman CK36-1A outdoor air conditioner and heat pump unit, the most commonly replaced items are electrical start components, fan-related parts, and wear items that reduce vibration or cause noise. Use the parts diagram in the owner's manual to match the exact component to your unit.

Most common replacements on outdoor condenser units

These are the parts we see replaced most often on systems like the CK36-1A:

  • Run capacitor / start capacitor (hard starting, humming, fan will not spin)
  • Contactor (relay) (unit will not turn on, chattering, burned contacts)
  • Condenser fan motor (overheating, fan not running, loud squeal)
  • Fan blade (wobble, vibration, scraping)
  • Dual run capacitor wiring and terminals (loose, overheated, corroded connections)
  • Vibration isolators and grommets (rattling, metal-on-metal noise)
Model-specific parts you can order for CK36-1A

This model page currently lists a couple of commonly needed maintenance and vibration-control items:

Quick “symptom to part” guide
Symptom Most likely area What to check first
Outdoor fan not spinning Fan circuit Capacitor, fan motor, wiring
Buzzing but will not start Start components Capacitor, contactor
Rattling or vibration Mounting and panels Screws, fan blade, grommets
Trips breaker or shuts off Electrical Wiring damage, motor/compressor load
Why it matters

Replacing the right part quickly prevents repeat shutdowns, protects the compressor from overheating, and reduces nuisance noise. Small items like a grommet can stop vibration wear that eventually damages wiring or refrigerant lines.

Last updated: February 2026

Most common symptoms to help you fix your dishwashers

Choose a symptom to see related dishwasher repairs.

Main causes: light switch beside the sink turned off, lack of power, bad dishwasher door switch, control system failure,…

Main causes: damaged or stuck spray arm, leaking door seal, damaged door hinge, leaky heating element water seal, cracke…

Main causes: improper loading, low water temperature, improper detergent dosage, detergent dispenser failure, spray arm …

Main causes: glass or popcorn kernel stuck in the chopper blade, drain line vibrating against the cabinet, debris in was…

Main causes: broken door latch, tripped circuit breaker, broken heating element, faulty vent fan, sensor failure, contro…

Main causes: not using rinse aid, rinse aid dispenser failure, broken heating element, malfunctioning vent, drying fan f…

Main cause: damaged rack height adjuster…

Main causes: clogged kitchen sink drain, clogged drain hose, drain check valve damaged, drain pump failure, control syst…

Main causes: water supply problem, stuck overfill float, clogged water inlet valve screen, water inlet valve failure…

Most common repair guides to help fix your dishwashers

These step-by-step repair guides will help you safely fix what’s broken on your dishwasher.

How to replace a dishwasher door latch assembly

How to replace a dishwasher door latch assembly

If the dishwasher door doesn't click shut, a broken door latch is a likely cause. Follow these instructions to replace i…

Repair time and Difficulty

 30 minutes or less
How to replace a dishwasher thermal fuse

How to replace a dishwasher thermal fuse

A completely dead control panel often indicates that the thermal fuse on the electronic control board is blown; follow t…

Repair time and Difficulty

 15 minutes or less
How to replace a dishwasher control panel

How to replace a dishwasher control panel

Learn how to replace a dishwasher control panel. Learn which tools and parts you need and get step-by-step instructions.…

Repair time and Difficulty

 15 minutes or less

Effective articles & videos to help repair your dishwashers

Use the advice and tips in these articles and videos to get the most out of your dishwasher.

What's a turbidity sensor, and how does it affect wash quality?

What's a turbidity sensor, and how does it affect wash quality?

Your dishwasher’s secret weapon? A turbidity sensor. Find out what it does, how it boosts wash quality, and what to do i…

Dishwasher not drying dishes video

Dishwasher not drying dishes video

Find out why your dishes are still wet even after the dishwasher cycle has finished.…

Replacing dishrack rollers on Kenmore 587-series and Frigidaire dishwashers video

Replacing dishrack rollers on Kenmore 587-series and Frigidaire dishwashers video

It only takes a few minutes to get your dishrack sliding easily again.…

Parts & More

Dryer
Gas Leaf Blower
Gas Range
Laundry Center
Parts
Top-Mount Refrigerator
Treadmill
Washer